USRID-16 – SINGLE-USE DISPLAY USB PDF TEMPERATURE RECORDER

CDN$38.00
Write a Review
SKU:
USRID-16
Adding to cart… The item has been added

FEATURES

  • Integral USB connector – no separate Interface Cradle required.
  • Suitable for multiple independent receivers, clinical trials and last-mile distribution.
  • Automatically generates an encrypted LogTag data file for a more detailed analysis.
  • Up to 16,000 recordings – enough for the longest trip.

Brochure

SPECIFICATIONS

Product Model USRID-16.
Sensor Measurement Range -30°C to +60°C (-22°F to +140°F).
Operating Temperature Range -30°C to +60°C (-22°F to +140°F).
Storage Temperature Range 0°C to +40°C (32°F to +104°F).
Rated Temperature Reading Accuracy Better than ±0.5°C for -5°C to +30°C (23°F to +86°F).
Better than ±0.8°C or better for measurements in other areas of rated range.
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution Better than 0.1°C/F.
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 7 minutes (T90) in moving air (1m/s).
Recording Capacity 16,129 temperature readings. 26.6 days @ 5min logging, 80 days @ 15min logging.
Sampling Interval Configurable from 30 seconds to 18 hours.
Logging Start Options Push button start or specific date & time. Optional start delay of 1 minute to 72 hours.
Recording Indication ‘REC’ symbol on display.
Alarms 1 upper and 1 lower alarm.
Download Time Typically with full memory (16.129 readings) in less than 20 seconds from time of insertion to availability of PDF report.
Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured).
Environmental IEC 60529: IP64 with USB cap fitted.
Power Source CR2032 3V LiMnO2 Battery (Non-Replaceable).
Battery Life 2 years storage, followed by 6 months normal use.
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Connection Interface USB 2.0, A-type plug.
Software PDF Reader, LogTag® Analyzer 2.5 or higher.
Size 93mm(H) x 54.5mm(W) x 8.6mm(T) including protective USB cap.
Weight 31g.
Case Material Polycarbonate.

Compliance and Certifications
FDA CFR21 Part 11 FCC EMC Directive CE EMC Directives Conforms to RoHS